Lennox nomenclature model number.

41.5 hp motor is required with the ZA05 and ZA06 drive kits. Raider®Packaged Gas / Electric 3 to 6 Tons / Page 14. SPECIFICATIONS BELT DRIVE MODELS - 6 TON. General Data Nominal Tonnage 6 Ton 6 Ton Model No. ZGB074S4B ZGB074S4T. Efficiency TypeStandard Standard Blower TypeSingle Speed Belt Drive Two Speed Belt Drive.

Lennox nomenclature model number. Things To Know About Lennox nomenclature model number.

MODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual …DMAIC Model - The DMAIC model is commonly used in the Six Sigma process. Learn the ins and outs of the DMAIC model and how it applies to business optimization. Advertisement Proce...The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics. GCS16-090-350-2Y GCS16 is the Series, 090 is the Cooling Capacity ...The best barcode label printers include models from Zebra, Star Micronics, Epson, and more. Read our full guide for details. Retail | Buyer's Guide REVIEWED BY: Meaghan Brophy Meag... Model Number Catalog Number Unit Model No 092 102 120 150 CONTROLS NOTE - Also see Conventional Thermostat Control Systems on page <?> for additional options. Smoke Detector - Supply or Return (Power board and one sensor) C1SNSR44B-2 11K76 X X X X Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43B-2 11K80 X X X X

Copeland Scroll refrigeration compressors (such as ZBxxKA-PFV) are designated by a "Z" in the first position of the model number. The second position determines the application range (B = high/medium temperature, S = medium temperature, F = low temperature).Lennox® packaged rooftop units represent some of the most innovative technology in the market. Combining industry-leading efficiency with fast, easy installation and service, Lennox continues to offer reliable systems that deliver exceptional comfort in commercial buildings. ... Model L™ Tonnage. 3-25 TONS. SEER/IEER. Up To 22.5/23.3. EER ...

Handbook on Orchid Nomenclature and Registration Cambridge University Press Charlotte Lennox (c. 1729-1804) was an eighteenth-century English novelist whose most celebrated work, The Female Quixote (1752), is just one of eighteen works spanning a forty-three year career. Susan Carlile's critical biography of Lennox focuses on her role

MODEL NUMBER IDENTIFICATION LF 24 - 200 A Unit Type LF = Lennox Unit Heater Series Nominal Gas Heat Input 100 = 100,000 Btuh 115 = 115,000 Btuh 145 = 145,000 Btuh ... Lennox LF24 gas-fired, horizontal unit heaters are compact in design and easy to install. Units feature steady-state heating efficiencies of up toThe new Model L™ is the most powerful, most advanced rooftop unit in the industry. Advanced Industry LENNOX WEBINARS. Register to receive information about our webinars! ... Lennox Global. Address: 11420 N Kendall Drive, Suite 103 Miami, FL 33176. Phone: +1 305-718-2901. CONNECT WITH US (opens in new window) (opens in new window)Cat # : 44K03. Model/Part # : 10ACB24-11P. Product Unavailable. Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart. Save to List.2) Look for a sheet taped to the front of the air handler (indoor unit), where the HVAC contractor has listed the performance data for the system. 3) Some manufacturers encode the SEER rating in the beginning of the model number on the data plate of the condenser. For example, the "XC21" at the beginning of the model number of the Lennox ...Lennox Model Number Nomenclature International Commission for the Nomenclature of Cultivated Plants Inspecting HVAC Systems Nick Gromicko,2016-08-20 Antique Electric Waffle Irons 1900-1960 William George,2003 Finally. A comprehensive collector's book and historical reference containing everything there is to know about antique and vintage ...

IBIO stock will go through peaks and valleys, but it's still a spec play lacking fundamental strength. Day traders should have fun, though. Covid-19 is pushing iBio stock to unprec...

FEATURES ALL MODELS Item LHA 090 LCA/LGA 102 LCA/LGA/LHA 120 LCA/LGA 150 Air Flow Choice — Bottom (down-flow) or *horizontal (side) supply and return air Standard Standard Standard Standard Bottom Power Entry — For electrical and gas lines Standard Standard Standard Standard Cabinet — Heavy gauge galvanized steel, fully insulated, powdered enamel paint fin-

Lennox, Air Conditioner, T CLASS, 4 Ton, 14 SEER, 1 Stage, 208-230 VAC 3 Ph 60 Hz, TSA048S4N44Y. Cat # : 14V84. Model/Part # : TSA048S4N44YBreakdown the model number to know what the model number tells you. The most important is knowing the SEER rating and Tonnage (size).This is how to decode it: Bryant unit model: #561CJ048. 561 - series (10 SEER R22 unit) 048 - 4 ton nominal cooling capacity. Model Number: #355BAV060100. 355 - series. B - model (multipoise)UNCASED AND FULL CASED UP-FLOW EVAPORATOR COILS (Air Conditioning Only) COILS/BLOWER COIL UNITS. ENGINEERING DATA. Nominal Size - 1.5 to 5 Ton (5.3 to 17.6 kW) Typical Application. Utility Room Installation With C23 Uncased Coil, furnace, electronic air cleaner and humidifier. Bulletin No. 210049 April 2000.I need the year and date that my parent's Lennox was installed. Our parents bought the home in 1976, but, along with my siblings. The house was built in 1968. The Serial Number on this unit is 5899D-32249. The Model Number is H526-03-2P. I need this information to complete a new insurance policy.10 years on compressor. 20 years or Limited Lifetime on heat exchanger (depending upon model) Lennox Merit ® Series products. 5 years on covered components. 5 years on compressor. 20 years on heat exchanger. Healthy Climate ® Indoor Air Quality Systems. 2 or 5 years on covered components (depending upon model)FEATURES. Application. − Provides installation versatility and maximum efficiency in cooling performance, air handling and filtering in cooling or heat pump ap plications. − Available in two model styles, upflow supply air discharge (CB17) or horizontal supply air discharge (CBH17). − Equipped with multi−circuit evaporator coils ...Lennox Model Number Nomenclature International Commission for the Nomenclature of Cultivated Plants Inspecting HVAC Systems Nick Gromicko,2016-08-20 Antique Electric Waffle Irons 1900-1960 William George,2003 Finally. A comprehensive collector's book and historical reference containing everything there is to know about antique and vintage ...

2 to 5 Ton (7.0 to 17.6 kW) Rooftop Installation with Horizontal Economizer Rooftop Installation With Economizer and Combination Supply and Return Air System. GCS20 Basic Unit. MODEL NUMBER IDENTIFICATION. 120. Minor Revision Number. GCS Y. Unit Type GCS = Packaged Gas Heat/Cooling Unit 0361. Cooling Capacity Tons (kW) 024 = 2 (7.0) 030 = 2.5 ...13ACX Air Conditioner. Economical, environmentally responsible home cooling. Even in the hottest summer months, the 13ACX-060-230 works efficiently to enhance your customers' comfort. Compared to an older system, this air conditioner can help them save significantly on their monthly cooling bills. ALL REGIONS. Energy Efficiency. Quiet Operation.Lennox REAL™ - Product Sales Sheet. New Product Innovation! One-pager sales talking points for REAL. Sales sheet ... Quick reference guide. Nov 28, 2023 (opens in new window) Model L Rooftop Unit Quick Reference Guide. Model L Rooftop Unit Quick Reference Guide. Model L™ Ultra-High Efficiency Rooftop Units Quick reference guide. …Lennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.EL296UHV(X) series units are 90% efficiency gas furnaces used for upflow or horizontal applications only, manufac­ tured with Lennox Duralok heat exchangers formed of aluminized steel. EL296UHV(X) units are available in heat­ ing capacities of 44,000 to 132,000 Btuh and cooling ap­ plications up to 5 tons.

MODEL NUMBER IDENTIFICATION 1 Indoor coils with the same letter designation will physically match the furnace. AFUE 80 = 80% Low NO x X = Units meet California Nitrogen Oxides Standard (40 ng/J) Cabinet Width A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. PRODUCT SPECIFICATIONS ML180UH UPFLOW/HORIZONTAL GAS FURNACESLennox DMS3 & DMS4 Nomenclature DMS 3 275 - 350     Model – MZ DMS – direct multi-zone system Series 3 or 4 Heating Section Natural Gas or LP 275 Mbh input 300 Mbh input 350 Mbh input 500 Mbh input Cooling Capacity 700 Mbh input 185 – …

NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. ... Model Number HS29−072 HS29−090 HS29−120 HS29−180 HS29−240COMMERCIAL Bulletin No. 490172 PRODUCT SPECIFICATIONS Supersedes July 2020. Bulletin No. 490172 March 2021. Supersedes July 2020. 26 to 44 kW (7.5 to 12.5 Ton) Net Cooling Capacity − 22.4 to 36.7 kW (74 500 to 123 300 Btuh) Optional Electric Heat - 5.7 to 45.9 kW. K C A 120S 4 BN 2 M. Brand/Family K = Landmark®. SEER up to 14.0 1.5 to 5 Tons Cooling Capacity − 17,500 to 60,000 Btuh. MODEL NUMBER IDENTIFICATION. 13 AC D 024 −. Unit Type AC = Air Conditioner Series Cooling Capacity − Tons 018 = 1.5 024 = 2 030 = 2.5 036 = 3 042 = 3.5 048 = 4 060 = 5 Nominal SEER Minor Revision Number. 2. Voltage 230 = 208/230V−1phase−60hz. NOTE − Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. ... Model Number HS29−072 HS29−090 HS29−120 HS29−180 HS29−240Available as a gas/electric, electric/electric or heat pump model; Improved comfort with an optional patented reheat dehumidification system; Quieter operation and easier services with a standard isolated compressor compartment and slide out blower on 7.5 ton and up; ... a Lennox International Inc. Company 1-800-448-5872Brand info that may help determine an age or era. Select one of the drop-down lists below. that corresponds to the 1st letter. of your HVAC brand name. Then make your selection from the Brand Names list. HVAC - A. HVAC - B. HVAC - C. HVAC - D.Lennox Model Number Nomenclature is available in our digital library an online permission to it is set as public as a result you can download it instantly. Our digital library saves in merged countries, allowing you to acquire the most less latency times to download any of our books next this one. Merely said, the Lennox Model Number ...

60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C. Bulletin No. 210445 July 2008. Supersedes February 2008. 2 to 6 Tons Net Cooling Capacity − 23,400 to 72,000 Btuh Optional Electric Heat − 7.5 to 30 kW. ASHRAE 90.1 COMPLIANT. MODEL NUMBER IDENTIFICATION. TCA060 S 2 B N 1 Y. Major Design Sequence A = 1st Generation B = 2nd Generation ...

102, 120 & 150 MODELS “LCA” PACKAGED COOLING & ELECTRIC HEAT “LGA” PACKAGED COOLING & GAS HEAT “LHA” PACKAGED HEAT PUMP *Net Cooling Capacity - 101,000 to 138,000 Btuh (29.6 to 40.4 kW)

So, all of the units that are the same model should also have the same model number. Model numbers are important to the Lennox company, as they signify the age, size, and warranty information for the HVAC unit. ... On the low side, the Lennox 16ACX model has a SEER rating of 14-17. Still, this is average in comparison to other HVAC systems. On ...Lennox® packaged units come appointed with: A packaged unit is your all-in-one solution that delivers gas heating for cold weather and electric cooling for hotter days. Compact footprint that allows for quick installation and seamlessly blends with your outdoor environment. Consistent temperature and reliable cooling comes standard thanks to a ...lennox industries model number chart air handling (cb 31 w-41-1p) cb31mv41- p voltage 1 phase -60 ez g 3 phase - 60 minor revision number ca?acity sae as cond- units model description cb = col-blower m = multi-position v = variable spf-ee modetjsÉrles 29 = standard 30 efficiency 31 = vanable speed 17 = conmercial 1 31 46 65 95 = 135 = 10 ton©2017 Lennox Industries Inc. Dallas, Texas, USA 506476-01 04/2017 Supersedes 03/2017 ML193DF SERIES GAS FURNACE WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional HVAC installer orEL296UHV(X) series units are 90% efficiency gas furnaces used for upflow or horizontal applications only, manufac­ tured with Lennox Duralok heat exchangers formed of aluminized steel. EL296UHV(X) units are available in heat­ ing capacities of 44,000 to 132,000 Btuh and cooling ap­ plications up to 5 tons.Are you in need of replacement parts for your Lennox furnace? Finding the right parts can be a challenge, especially if you don’t know where to start. Fortunately, using the model ...Are you in need of replacement parts for your Lennox furnace? Finding the right parts can be a challenge, especially if you don’t know where to start. Fortunately, using the model ... MODEL NUMBER IDENTIFICATION TGA M090 S 2 B S 1 Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − kW 090 = 26.4 kW 102 = 29.9 kW 120 = 35.2 kW 150 = 44.0 kW Cooling Efficiency Lennox G26Q4/5-125 Installation Instructions Manual (31 pages) Brand: Lennox | Category: Industrial Equipment | Size: 0.64 MB. Lennox G26Q4/5-125 Pdf User Manuals. View online or download Lennox G26Q4/5-125 Unit Information, Installation Instructions Manual.

102, 120 & 150 MODELS “LCA” PACKAGED COOLING & ELECTRIC HEAT “LGA” PACKAGED COOLING & GAS HEAT “LHA” PACKAGED HEAT PUMP *Net Cooling …A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is rated at 2.5 tons.MODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual units ...Instagram:https://instagram. how to do post spin 2k23 next gen1st birthday cake walmartdid moon and tiko break up 2023burlington county times in nj To determine the age of your Lennox HVAC system, focus on the serial number’s third and fourth digits, representing the year of manufacture. Following these, a letter denotes the month, with ‘A’ for January and continuing alphabetically to ‘M,’ excluding ‘I.’. For instance, in serial 1919H16627, “19” signifies the year 2019 ... steven macon greerhollywood nails dracut ma Lennox DLSC SL280V, SL280UH090V36B, 80% AFUE, 88000 BTU, 3 Ton, 2 Stage Heat, Variable Speed Upflow/Horizontal Gas Furnace. Cat # : 78W69. Model/Part # : SL280UH090V36B melissa patterson murderer Model Number Catalog Number Unit Model No 092 102 120 150 CONTROLS NOTE - Also see Conventional Thermostat Control Systems on page <?> for additional options. Smoke Detector - Supply or Return (Power board and one sensor) C1SNSR44B-2 11K76 X X X X Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43B-2 11K80 X X X XGas Valve Operation (figures 2 and 3) 1− Set thermostat to lowest setting. 2− Turn off all electrical power to appliance. 3− This furnace is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 4− Open or remove the heat section access panel.